Product FAQ´s LanExpert

The Frequently Ask Questions are organized into their respective sections as they pertain to the LanExpert.



STRESS TEST


Question
Can I use only one tester to make RFC2544 and traffic generate? if so, which mode would I choose?
Answer

You can run the Stress Test using the two ports on one LanExpert. The Independent Mode must be selected to do the Stress Test with a single LanExpert. You can also conduct the Stress Test using two LanExperts. One unit is designated as the remote unit and both are set to the Single Ended Mode.

Question
Normally, how much time is needed to do a RFC2544 test? What does estimated time mean in every item of RFC2544?
Answer

To conduct a test that meets 100% of the RF2544 requirements would take about 2.5 days of continuous testing. This is typically only done in a laboratory environment and rarely (if ever) done in the field. Field tests are almost always customized by the user to provide a thorough test within a more reasonable time frame. For example, the RFC2544 requires testing with eight different packet sizes. A typical field test will reduce the number of different packet sizes, many times only using the largest and smallest packet size, which greatly reduces the test time. The test times shown for each test on the LanExpert are for the default settings, which we have picked for field tests. As the user changes the test parameters these estimated times will change so that the total test time is known before the tests are started.

Don't see the question or answer that fits your issue?
Send us your question and we'll respond with an answer.